Sloped or not each segment of the roof shall be capable to carry the loading created due to blockage of the primary roof drainage system of that segment plus the load caused by water that rises above the inlet of the secondary drainage system at its design flow rate.
Rain loading configuration on a roof.
The secondary drains are located 1 5 in.
Determine the design rain load on the roof of a building that is 250 ft wide and 500 ft long.
2014 fbc building 5 th edition 16 structural design 1611 rain loads 1611 1 design rain loads jump to full code chapter each portion of a roof shall be designed to sustain the load of rainwater that will accumulate on it if the primary drainage system for that portion is blocked plus the uniform load caused by water that rises above the inlet of the secondary drainage system at its design flow.
This is highly regional as weights of snow for example range from 10 to 300 pounds per square foot based on moisture and volume of the snow.
It is not the fault of your contractor and while the delays can certainly be frustrating a contractor who attempts to install a new roof in the rain is going to be compromising the overall integrity of the installation.
During a roof installation there are several steps to ensure that your home s interior is never exposed.
This is all of the natural stresses imposed upon a roof such as snow loads rain loads and wind loads.
Should your roof installation have to be delayed due to poor weather be patient.
Determine the transient load of the roof.
D s depth of water on undeflected roof up to the inlet of the secondary drainage system.
For a building in northern vermont snow is likely the controlling roof live load.
Above the roof surface primary drain.
The key to managing rain loads in buildings is roof drainage including a primary drainage system and a secondary drainage system which is set at an elevation higher than the primary system to drain any water that builds up after the lower system is blocked or not working.
Diameter drains spaced uniformly along the long sides of the building at 40 ft intervals for the secondary drainage system.
Until recently floor live load roof live load roof snow load wind load earthquake design data and flood loads were required to be listed on the construction documents.
Note that although rain loads are covered in ibc section 1611 they were not required to be listed on the construction documents.
While the completed shingles may not be in place during an unpredicted rainstorm there should be a protective layer on your roof that keeps rain from getting in.
Asce 7 says that the rain load is 5 2psf in h s h d.
D h additional depth of water above the secondary inlet undeflected roof at its design flow hydraulic head it appears as though this is applied as a uniform load when viewing the examples in the commentary.
In northern mississippi it may be rain.
The event that shall be considered is an intense short duration rainfall.
During its lifetime a building roof is subjected to a number of different structural loads roof dead loads and roof live loads principally snow wind and rain.